Building a Fire-Resistant Home in the Palisades

3062 Dannyhill Drive, a B Homes Design & Development residence in Cheviot Hills, Los Angeles

Pictured: 3062 Dannyhill Drive, a B Homes residence.

The Pacific Palisades is a Very High Fire Hazard Severity Zone. Every home rebuilt there must be designed to resist wildfire, and the rules changed this year.

A new code

For two decades, California's wildfire construction rules sat in Chapter 7A of the Building Code. On January 1, 2026, they moved into a standalone code: the California Wildland-Urban Interface Code, Title 24, Part 7. It is based on the 2024 International Wildland-Urban Interface Code. Most of the core requirements carried over from Chapter 7A, but plans and specifications should now reference the new code.

What it means for a house

In broad terms, the code addresses each way fire attacks a building:

  • Roof. A Class A roof assembly. Tile, metal and other coverings can qualify when installed as a listed assembly.
  • Vents. Embers enter through vents more often than people think. Vents must be listed or tested for ember and flame resistance, and roof vents use fine, noncombustible mesh.
  • Walls, eaves and soffits. Ignition-resistant or noncombustible materials.
  • Windows and doors. Tempered, dual-pane glazing and rated or solid-core exterior doors.
  • Decks. Decking near the house must meet wildfire standards.

Zone 0: the first five feet

Research on how homes ignite points to embers landing close to the house: in mulch, on a doormat, against a wooden fence. California law calls for an "ember-resistant zone" in the first five feet around a home, known as Zone 0.

The Board of Forestry adopted Zone 0 rules in August 2026, withdrew the package for revisions, and re-adopted a revised version on November 5, 2026. As of this writing, the rules are not yet in effect. When they take effect, they are expected to apply first to new construction, with existing homes phased in later. The adopted rules prohibit combustible mulch, debris and new combustible fencing within that five-foot band, among other provisions.

Our advice: design the first five feet as if the rule were already in effect. Gravel, pavers and concrete next to the house cost little at the design stage and are a nuisance to retrofit later.

Beyond the minimum

The code sets a floor. Choices that add resilience:

  • Fewer, simpler roof valleys where debris collects
  • Enclosed eaves rather than exposed rafter tails
  • Metal gutters with guards
  • Noncombustible siding such as stucco, fiber cement or stone at the base of walls
  • Interior fire sprinklers, required in new California homes, which protect occupants if fire gets inside
  • A clear plan for the landscape, so the yard does not carry fire to the house

Beauty and resilience

A fire-resistant house does not have to look like a bunker. Stone, plaster, steel windows and clay or metal roofs are among the most beautiful materials in Southern California architecture, and among the most fire-resistant. Good design makes the safe choice the handsome one.

To talk through materials for a Palisades rebuild, get in touch.

Sources: California Building Standards Commission; International Code Council; California Board of Forestry and Fire Protection. This is general information. Your architect, engineer and LADBS determine the requirements for a specific project.


Planning a home in West Los Angeles? Talk with Bob Skibinski, licensed general contractor, about your lot or your plans. Start a conversation or call 310-895-7701.

Previous
Previous

Buying a Lot in the Pacific Palisades: A Due-Diligence Checklist

Next
Next

EO1 or EO8: Choosing Your Palisades Rebuild Path